- 54 -
SERIAL No.,0710001
DATA No.,TORQUE[Nm],TIME[hh:mm:ss],DATE[YYYY/MM/DD],OVERLOAD,OPERATION,Remark_1
1,800,16:21:00,2007/12/01,PowerON,
2,801,16:22:31,2007/12/01,ZeroAdjustment,
3,799,16:23:20,2007/12/01,,AutoStart,
4,800,16:24:15,2007/12/01,,AutoStart,
5,799,16:25:31,2007/12/01,,AutoStart,
・・・・・・・・・・・・・・・・・・・
998,1001,23:58:59,2007/12/01,ErrorOverLoad,AutoStart,
999,800,23:59:59,2007/12/01,ZeroAdjustment,
(ファイルの最後)
Storage Format of Group File
The serial number of “DIGITORQON” is placed at the top of the group file.
In the group file, data is arranged in CSV (comma separated value) text format
and in the order of DATA No., TORQUE (tightening torque), TIME (hour, minute,
second), DATE (year, month, day). A data line is added as another tightening
torque measurement is carried out.
The maximum number of tightening torque data that can be in a group file is 999
(up to TORQUE DATA No. 999). The next data will be saved in a new group file
having a serial number larger than that of the old file by 1.
By pressing MENU
button and then running
(Change group file), change the group file to which tightening torque data are
saved.(See page)
NOTE Tightening torque data management can be done to read in the microSD memory
card with available spreadsheets.
NOTE To read data folder and group file stored on microSD memory card on a PC, a
memory card reader compatible with microSD memory card/SD memory card
is required
NOTE microSD memory card can store the following data.
Storage Condition
Target
Size of 1 group file (tightening torque = 999)
Approx. 82KB
Number of pieces saved on microSD memory card (1GB) Approx. 13 million
NOTE TransFlash Card compatible with the microSD memory card is also enable on
“DIGITORQON”
DATA No. TORQUE[Nm] TIME[hh:mm:ss]
1
800
16:21:00
2
801
16:22:31
3
799
16:23:20
4
800
16:24:15
5
799
16:25:31
998
1001
23:58:59
999
800
23:59:59
・・・・・・・・・・・・・・・・・・・
Open Group File with