- 12 -
CAUTION
● Reaction force must be taken by area beyond “a” dimension when
L-type reaction plate is used. See table below.
There is a chance to invite overload when
reaction force is taken within
“
a
”
dimension
which may result in breakage of the HSH set
screws, seizure of the output square drive or
loss of torque precision.
Model
a (mm)
PDX-301N/PDX-302N/PDX-301F
130
PDX-501N/PDX-502N/PDX-501F
135
● Fully slide the socket over the bolt/nut.
Insufficient socket engagement may cause
damage to the bolt/nut or slip off of the
socket which may result in injury or
malfunction of the wrench.
●
Do not operate wrench in extremely high or low temperature.
Refer operating temperature in the specification.
Failure to follow this instruction may result in accident, malfunction or loss
of torque precision.
a