CAUTION
● Keep good motor ventilation.
□ Do not put any foreign materials in the vent.
□ Do not cover the vent.
● Do not connect multiple plugs to a single outlet by using multiple
outlet adaptors.
Over current may cause fire, accident or malfunction.
● Provide leakage breaker as a shock guard for each wrench.
□ Use of leakage breaker is not mandatory for double insulated
wrenches, however, it is recommended for safety reason.
● When using an extension cord, make sure that voltage remains
/- 10% of the rated voltage at all time.
● Extension cord must be selected from a list below.
As the distance from the supply outlet increases, a larger gauge
extension cord must be used. Using extension cord with inadequate
size causes a serious drop in voltage, resulting in loss of power and
overheating.
Nominal Conducting
Cable Cross Section
Max. Length
115V
230V
H07RN-F
1.5mm
2
10m
20m
2.5mm
2
20m
40m
4.0mm
2
30m
60m
AWG 14
50ft
100ft
AWG 12
80ft
160ft
AWG 10
130ft
260ft