MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
EN
46
www.mythomson.com
In phase 1, motor M1
reached the stop after
opening for less than 3s:
reduce the speed.
In phase 1, motor M2
reached the stop after
opening for less than 3s:
reduce the speed.
In phase 1, panel M1 did
not reach a stop after
opening for 60s or cable
section too weak?
In phase 1, panel M2 did
not reach a stop after
opening for 60s or cable
section too weak?
In phase 1, motor M1 was
not detected (contact
failure, electronic card
problem?)
Review motor
connections.
In phase 1, motor M2 was
not detected (contact
failure, electronic card
problem?)
Review motor
connections.
In phase 1 (opening),
M1 is not recognised.
Note 1
.
In phase 1 (opening),
M2 is not recognised.
Note 1.
In phase 2 (closing), M1
is not recognised.
Note
2.
In phase 2 (closing), M2
is not recognised.
Note
2.
Self-learning was
interrupted by the user.
Note 1:
many possible causes:
• The motor was not recognised as compatible
with the electronic card.
• There is a fault in the motor.
• The section of the motor cable is too weak
• A gust of wind prevented the system from
recognising the motor.
Repeat the self-learning procedure and assist
the panel opening process during the start of
phase 2 if wind speed remains high.
Note 2:
many possible causes:
• The motor was not recognised as compatible
with the electronic card.
• There is a fault in the motor.
• The section of the motor cable is too weak.
Try again by repeating the self-learning
process.
2.8. Programming remote controls
It is possible to open both panels (gate) or a
single panel (pedestrian) by remote control.
On a remote control, it is possible to decide
which button will be used as the gate command
and which button will be used as the pedestrian
command.
2.8.1. Programming with the card
Note:
It is possible to programme a remote control
once, then use the “copy” function that allows
you to programme additional remote controls
without using the electronic card, via a remote
control that has already been programmed.
(This is useful when additional remote controls
are available for programming without having to
open the electronic control box).
Programming a button for the GATE
OPENING command:
• Press “–” for 3 seconds and L1 will switch on.
• Press
OK
and L1 and L4 will turn on alternately.
• Within the next 10 seconds, press the remote
control button for memorisation.
• If the red LEDs all turn on for 1 second, this
means that memorisation is successful.
D - BEGINNING OPERATION