45
EN
EN
www.mythomson.com
MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
D - BEGINNING OPERATION
IMPORTANT
• The panels must have fixed stops at the end
of the closing motion (central stop) and at the
end of the opening motion (side stops), during
self-learning, and they must not be moved or
removed afterwards. If the stops are not firmly
attached to the ground, this can lead to self-
learning failure.
• The panels can be in any position (open,
closed, ajar) before starting the self-learning
procedure.
SECURITY
Make sure that there is no one in the gate
movement area during the entire commissioning
period and the entire test period.
Starting self-learning
• Check that you are not in a prog menu by
pressing on prog 3 consecutive times.
• Press and hold the “
+
” button for 3 seconds.
The self-learning procedure may be interrupted
at any time by pressing OK.
Self-learning procedure
• The flashing light flashes.
•
Phase 0
: repositioning in central stop
Panel M2 closes up to the central stop.
Panel M1 closes up to the central stop.
•
Phase 1
: detection of side stops
Panel M1 opens up to the side stop.
Panel M2 opens up to the side stop.
•
Phase 2
: path detection
Panel M2 closes again up to the central stop
Panel M1 closes again up to the central stop.
•
Phase 3
: learning opening and closing
Panel M1 starts to open, gradually accelerating.
Panel M2 starts to open, gradually accelerating,
2.5 seconds (or more depending on the setting,
see MENU 3) after M1.
The panels reach their opening stops.
Panel M2 starts to close, gradually accelerating.
Panel M1 starts to close, gradually accelerating.
The panels reach the central stop (with a
difference of 2.5 seconds or more depending on
the setting, see MENU 3)
Error during self-learning
If self-learning does not work as described
above and stops earlier than expected (the
motors and the flashing light stop), some of the
red LEDs will be on or flashing, and others will be
off. The configuration of the red LEDs that are
on provides an error code allowing the installer
to determine the source of the incident that has
occurred.
Below is a table indicating the self-learning error
codes:
: LED off
: LED on
: Flashing LED light
Make sure not to confuse the self-learning
error codes with error codes of events that
may occur during normal operation and
which are indicated in the same way by
a combination of red LEDs that are on /
off / flashing.
(See page 47)
L1
L2
L3
L4
Description
In phase 0, panel M1
did not arrive at a stop
after closing for 60s,
disengagement or cable
section too weak?
In phase 0, panel M2
did not arrive at a stop
after closing for 60s,
disengagement or cable
section too weak?
In phase 0, motor M1
was not detected (not /
incorrectly connected?).
In phase 0, motor M2
was not detected (not /
incorrectly connected?).