15
EN
EN
www.mythomson.com
MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
C - INSTALLATION
If the positive distance
D
is greater than 200 mm or if distance D is negative, the configuration of the
posts must be adjusted.
Determine the opening angle of each panel based on the data in the following table.
The opening angle may be different for each panel but must never be less than 40°.
For
opening up to
Distance D
(in mm)
90°
-50 <
D
< 200
98°
-50 <
D
< 150
105°
-50 <
D
< 100
115°
-50 <
D
< 50
125°
-50 <
D
< 0
135°
-50
central stop
Inner side of the property
view from above
opening
angle
opening
angle
side
stop
D
D
3.1.2. For opening towards the outside of the property
D
D
central stop
Inner side of the property
view from above
opening
angle
opening
angle
90°
90°
side
stop
max. D = 100mm
max. angle 90°
3.2. Assembling the pivoting arm
Screw 9
Screw 9
Washers 22
Washer 22
Nut 15
Nut 15