17
EN
EN
www.mythomson.com
MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
C - INSTALLATION
• Use plugs and screws that are suitable for the post material (example: for concrete, use ø12mm
plugs and ø8mm lag screws with a length of 80mm). After tightening, the mounting bracket must
be completely horizontal and 14mm above the middle of the rigid part of the gate. Make sure not to
weaken the posts.
14 mm
x
axe du gond
• Depending on the maximum opening angle desired for the gate, the post bracket should be placed
further from or nearer to the edge of the post (so that the motor does not prevent the gate from
opening). For optimum motor operation, the distance
X
must be as small as possible. Also note that
a 25mm safety distance is required between the open gate and the motor
(see Chapter “Hazard
Analysis”)
. Temporarily place the motor on the ground in position and search for the correct position
to determine distance
X
.
25 mm
x