MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
EN
34
www.mythomson.com
L0
PROG
OK
+
-
L1
L2
L3
L4
+ -
BAT TRANS
GN
D
GN
D
PH
O
+24V
M1
-
M2
-
M1
+
M2
+
warn
-
warn
+
2B
6.4 - Photocells
• If there are no photocells, leave the connector between GND and PHO.
• With one set of photocells, remove the connector between GND and PHO.
photocell RX1
photocell TX1
+ -
BAT TRANS
GN
D
GN
D
PH
O
+24V
M1
-
M2
-
M1
+
M2
+
warn
-
warn
+
2B
~- ~+
~+
~-
NO COM NC
• With 2 sets of photocells, remove the connector between GND and PHO
+ -
BAT TRANS
GN
D
GN
D
PH
O
+24V
M1
-
M2
-
M1
+
M2
+
warn
-
warn
+
2B
~- ~+
~+
~-
NO COM NC
~- ~+
~+
~-
NO COM NC
photocell RX1
photocell TX1
photocell RX2
photocell TX1
C - INSTALLATION