Installation Instructions

for a “Pair” of gates...

THE FERNI-P KIT CONSISTS OF:

2 X FERNI MOTORS
1 X CONTROL PANEL
1 X RADIO FREQUENCY CARD
1 X TUNED ANTENNA
2 X REMOTE CONTROL TRANSMITTERS
1 X PAIR SAFETY PHOTOCELLS

Summary of Contents for Ferni Series

Page 1: ...0430 FAX 0115 921 0431 INTERNET www cameuk com E MAIL enquiries cameuk com TECHNICAL HELPLINE 0115 921 0430 Installation Instructions for a Pair of gates THE FERNI P KIT CONSISTS OF 2 X FERNI MOTORS...

Page 2: ...E KIT TO A PAIR OF GATES PLEASE READ THESE INSTRUCTIONS AND DIAGRAMS CAREFULLY BEFORE STARTING ANY WORK 1 UNDER NO CIRCUMSTANCES SHOULD THIS EQUIPMENT BE OPERATED UNLESS FITTED TO A GATE FAILURE TO CO...

Page 3: ...LLS 14 4 3 INSERTING THE FREQUENCY CARD 14 4 4 WIRING IN THE TUNED ANTENNA 15 4 5 CODING THE REMOTE CONTROLS 15 4 6 POWERING UP THE CONTROL PANEL 15 5 Stage 5 Commissioning the control Panel 5 1 INITI...

Page 4: ...GATE POSTS OR PIERS ARE STRONG ENOUGH TO SUPPORT THE GATES AND THE MOTORS THE GATES ARE STRONG ENOUGH TO BE AUTOMATED THE GATES SWING FREELY FROM OPEN TO CLOSE AND THERE IS NO FRICTION ON THE HINGS F...

Page 5: ...ROUGH THE POST THEN BOLTED 4 Fig 3 Fig 2 WHEN MOUNTING THE MOTOR PLATE BE SURE TO RESPECT THE 150mm DIMENSION FROM THE BOTTOM OF THE MOTOR PLATE TO GROUND LEVEL THIS IS TO ENSURE SUFFICIENT CLEARENCE...

Page 6: ...l PLEASE CHECK THAT YOU HAVE CORRECTLY Ref Page 1 Checked Requirements 1 1 3 2 Mounted Motor Base Plate 1 2 4 NOW STAGE 1 IS FULLY COMPLETED YOU ARE READY TO BEGIN STAGE 2 OF YOUR FERNI AUTOMATION KIT...

Page 7: ...asing with the screws supplied Plug the green connector from the transformer to the PCB ensuring that it connects the correct way NB FROG Series Motors connect the black wires coming out of the board...

Page 8: ...HEREBY AVOID UNNECCESSARY WATER INGRESS WHEN INSTALLING LOW VOLTAGE CABLE AROUND THE GATEWAY IT IS ADVISED TO PUT ALL LOW VOLTAGE CABLE IN EITHER DUCTING OR ALKATHENE PIPING ALL CABLE JOINTING SHOULD...

Page 9: ...K THAT YOU HAVE CORRECTLY Ref Page 1 Installed Basic Cable Layout 2 1 6 2 Installed Low Voltage Cable Layout 2 2 7 NOW STAGE 2 IS FULLY COMPLETED YOU ARE READY TO BEGIN STAGE 3 OF YOUR FERNI AUTOMATIO...

Page 10: ...INSERT THE MOTOR INTO THE MOTOR BASE PLATE IN ALIGNMENT WITH THE 4 PRE DRILLED HOLES AND FIX IT WITH THE TWO M8 X 110 BOLTS NUTS SUPPLIED FOR RIGHT HAND INSTALLATIONS REVERSE THE POSITION OF THE MOTOR...

Page 11: ...AFT IN PLACE BY TIGHTENING THE FOUR GRUB SCREWS TOP AND BOTTOM OF THE GEARBOX JOIN AND FIX THE TWO ARMS TOGETHER WITH THE WASHER AND THE M8 X 16 BOLT FIT THE CURVED ARM TO THE FRONT MOUNTING BRACKET U...

Page 12: ...AM UNTIL IT MAKES CONTACT WITH THE MICROSWITCH CLOSE THE GATE AND TIGHTEN THE SCREW IN THE CAM CLOSED POSITION RELEASE THE GATE MOTOR AND MOVE THE GATE TO THE DESIRED CLOSED POSITION NOW ROTATE THE LO...

Page 13: ...OU HAVE CORRECTLY Ref Page 1 Installed the Motors 3 1 9 2 Installed the Drive Arms 3 2 10 3 Adjusted the Open Closed Cams 3 3 11 NOW STAGE 3 IS FULLY COMPLETED YOU ARE READY TO BEGIN STAGE 4 OF YOUR F...

Page 14: ...13 STAGE 4 WIRING ELECTRICAL 2 4 1 Wiring the Motors ENSURE BOTH MOTORS ARE ADEQUATELY EARTHED Fig 11...

Page 15: ...Y BEAM TRANSMITTER IF FITTING A SECOND ARC LINE SET OF SAFETY BEAMS THEN C NC MUST BE WIRED IN SERIES 4 3 Inserting the Radio Frequency Card INSERT THE RADIO FREQUENCY CARD INTO THE SMALL SOCKET ON TH...

Page 16: ...POWER TO TERMINALS L1 L2 IN THE CONTROL PANEL L2 BEING LIVE ENSURE THAT THE CONTROL PANEL IS ADEQUATELY EARTHED ANTENNA WIRING POINT Fig 14 2 SET THE BANK OF DIPSWITCHES ON ALL REMOTES TO EXACTLY THE...

Page 17: ...RED THE MOTORS AS SHOWN 4 1 13 2 WIRED IN THE SAFETY PHOTOCELLS 4 2 14 3 INSERTED THE RADIO FREQUENCY CARD 4 3 14 4 WIRED IN THE TUNED ANTENNA 4 4 15 5 PROGRAMMED THE REMOTE CONTROLS 4 5 15 6 POWERED...

Page 18: ...CONNECT POWER TERMINALS L1 L2 AND A SUITABLE EARTH L2 BEING LIVE 2 SELECT THE MOTOR POWER SETTING ON THE TRANSFORMER TO LEVEL 1 FOR COMMISSIONING Fig 16 17 4 ENSURE HARD WIRE LINK IS FITTED BETWEEN TE...

Page 19: ...O TERMINAL 2 MOMENTARILY TOUCHING TERMINAL 7 1 MOMENTARILY PULSE TERMINALS 2 3 WITH A PIECE OF WIRE TRAILING FROM TERMINAL 2 AND MOMENTARILY TOUCHING TERMINAL 3 THE GATES SHOULD START TO OPEN IF THEY...

Page 20: ...N FOR A FURTHER 5 7 SECONDS AFTER THE MOVEMENT CYCLE HAS BEEN COMPLETED I E FULLY OPEN OR FULLY CLOSED 3 CHECK THE SENSITIVITY OF THE GATES BY TRYING TO PHYSICALLY STOP THE GATE AND ADJUST THE POWER S...

Page 21: ...MATICALLY CLOSE THE GATES AFTER 10 SECONDS AND FULLY CLOCKWISE WILL APPROX CLOSE THE GATES AFTER 80 SECONDS A SENSIBLE SETTING IS ABOUT HALWAY I E 6 O CLOCK POSITION WHICH WILL AUTOMATICALLY CLOSE THE...

Page 22: ...r card the signal LED will start to flash At the same time transmit on the top button of your remote control keep both the top button and the yellow receiver button pressed until the LED stops flashin...

Page 23: ...G HAS BEEN COMPLETED FIT THE MOTOR COVER WITH THE 4 X 3 9 X 13 SCREWS PROVIDED EMERGENCY RELEASE TO BE DONE WHILE THE MOTOR IS OFF IN THE CASE OF A POWER FAILURE OR MALFUNCTION UNLOCK THE GEAR MOTOR B...

Page 24: ...K IS FITTED BETWEEN TERMINALS 1 2 AND 2 C1 5 1 17 2 SET THE OPENING AND CLOSING TIMES FOR GATES 5 2 18 3 ADJUSTED THE CONTROL PANEL 5 3 19 4 IF REQUIRED ACTIVATED AUTOMATIC CLOSING AND SAFETY PHOTOCEL...

Page 25: ...RESTORE POWER 3 IF SAFETY BEAMS ARE NOT FITTED ENSURE THAT A HARD WIRE LINK IS FITTED BETWEEN TERMINALS 2 C1 4 REMOVE SAFETY BEAM WIRES 2 C1 FROM CONTROL PANEL AND CHECK IF YOU HAVE A NORMALLY CLOSED...

Page 26: ...TTING 4 OPERATOR PRESENT HAS NOT BEEN SELECTED TO DEACTIVATE RADIO REMOTE CONTROLS DIPSWITCH 1 5 WRONG FREQUENCY CARD FITTED FOR THE REMOTE CONTROL GATES WILL NOT RESPOND TO REMOTE CONTROL COMMAND IF...

Page 27: ...GGESTED WHEN THE GATE WING IS WIDER THAN 2 5M 2 00 m Weight of Gate Width of Motor 2 50 m 3 00 m 800 kg 600 kg 500 kg 3 50 m 4 00 m 450 kg 400 kg Type Weight Power Supply Torque Capacitor Nominal Curr...

Page 28: ...ettings To vary the motor torque move the indicated spade connector to one of the four position 1 min 4 max N B It is always best to start from position one and increase the torque setting as required...

Page 29: ...anel and Motors should be suitably Earthed Safety SAFETY BEAMS CAN BE CONNECTED TO OBTAIN Re Opening During closing 2 C1 if the beam is broken while the gate is closing they will reverse the direction...

Page 30: ...matic closing timer is automatically activated at the end of the opening cycle The pre set adjustable automatic closing time is automatically interrupted by the activation of any safety system and is...

Page 31: ...f they are not used they must be linked L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1 Co axial cable 230V A C M1 Single Phase motor Single Phase motor with leaf delay on closing cycle M2 11 TX 10 Safety beams...

Page 32: ...ors run on for between 6 and 8 seconds after the last gate has fully close Trimmer T C A Adjustment of automatic closing time from a minimum of 1 to a maximum of 120 seconds Trimmer T R 2 M Partial op...

Page 33: ...x 20W Contact N C for re opening during closing Antenna connection Power supply for control panel Connection for motor one delay in opening Connection for motor two delay on closing 230V A C 25W max o...