MOTOR DRIVE FOR 2-PANEL GATES - CONNECT
EN
30
www.mythomson.com
C - INSTALLATION
View from above
Inner side of the property
Perfect alignment
10 cm min
15 cm max
Inner side of the property
Inner side of the property
Inner side of the property
45mm
20mm
5.3 - 2
nd
set of photocells (optional)
For use when the gate is not visible. You must install a second set of photocells to prevent the gate from
opening when an item (car, person, etc.) is behind the gate.
Installation:
• The photocells must be perfectly aligned and parallel to each other.
• The reception photocells (RX indicated on the back) must be installed facing the motor post where the
electronic card is located (see drawing below).
• Additional photocells must be installed on the inner side for opening inward or on the outer side for
opening outward. The distance between the main edges of the gate in an open position at 90° and the
photocells must be between 10cm and 15cm maximum.
• The mounts used to secure the photocells must be correctly secured to the ground and precisely
aligned.
• The photocells must be placed exactly at the same height from the ground, and the height must be
between 30cm and 60cm.