UltiMate 3000 Series:
NCS-3500RS and NCP-3200RS
Page
244
Operating Instructions
Description
Part No.
6 column clips
2 clips to attach capillaries routed from top to bottom through the column chamber
Column switching valve
2-position, 6-port valve
2-position, 10-port valve
6041.0004
6041.0001
Column switching valve, rotor seal
→
Rotor seal
Column switching valve, stator
→
Stator
Drain kit for UltiMate 3000 systems
The kit includes all required components and detailed installation instructions.
6040.0005
Filter frit (PEEK, 10 µm) for solvent supply line filter (10 frits)
6268.0117
Filter frit (titanium, biocompatible, 2 µm, 2 frits)
For loading pump inline filter and ProFlow flow meter inline filter.
6268.0036
Fitting plug (Viper, titanium, biocompatible)
6040.2303
Flow meters:
ProFlow flow meter for nano LC (50 - 1500 nL/min)
Classic flow meter with flow selector for capillary LC (0.5 - 10 µL/min)
Classic flow meter with flow selector for micro LC (5 - 50 µL/min)
6041.7850
6041.7902A
6041.7903A
Flow selector (for Classic flow meters only) for
Capillary LC (0.5 - 10 µL/min)
Micro LC (5 - 50 µL/min)
6041.0003
6041.0014
Fuses kit, including:
10 fuses, 4A, slow-blow, 5 x 20 mm (for use in the NCS)
10 fuses, overload protection, 2A, slow-blow, 5 x 20 mm (for use in the NCP)
5 fuses, 4A, slow-blow, 6.3 x 32 mm
6820.0026
Inline filter (with filter frit, porosity: 2 µm) for loading pump
6042.5014
Inline filter, filter frits
→
Filter frits, inline filter
Installation tool for Viper capillaries with torque toothing
6040.2314
Installation tool for Viper capillaries with torque toothing
→
Tool, installation tool for Viper capillaries with torque toothing
Maintenance kit for NCS-3500RS loading pump—including:
4 solvent supply line filters with filter frits
1.5 m silicone tubing (O.D. x I.D. 2.80 mm x 1.30 mm)
18 cm PharMed tubing (O.D. x I.D. 3.2 mm x 1.6 mm)
3 tubing connectors, straight, for I.D. 1.0-2.0 mm
2 piston seals (reversed phase), main piston seals
2 piston seals, for plate of seal wash system
2 support rings
1 O-Ring seal each (PTFE; 9x1.5 and 32x1.5), for seal wash system
1 filter frit (titanium, biocompatible, 2 µm) for inline filter
1 valve cartridge
1 cap seal for purge screw (to be used
only
for screws
without
integrated cap seal)
5 cleaning swabs
6042.1951
Menu pen
6300.0100
Summary of Contents for Dionex UltiMate 3000 Series
Page 2: ...UltiMate 3000 Series NCS 3500RS and NCP 3200RS Operating Instructions ...
Page 8: ...UltiMate 3000 Series NCS 3500RS and NCP 3200RS Page vi Operating Instructions ...
Page 24: ...UltiMate 3000 Series NCS 3500RS and NCP 3200RS Page 16 Operating Instructions ...
Page 62: ...UltiMate 3000 Series NCS 3500RS and NCP 3200RS Page 54 Operating Instructions ...
Page 92: ...UltiMate 3000 Series NCS 3500RS and NCP 3200RS Page 84 Operating Instructions ...
Page 246: ...UltiMate 3000 Series NCS 3500RS and NCP 3200RS Page 238 Operating Instructions ...
Page 262: ...UltiMate 3000 Series NCS 3500RS and NCP 3200RS Page 254 Operating Instructions ...