18
CARE AND MAINTENANCE
INSPECTION AND SERVICE SCHEDULES
To ensure that your Thermo King unit operates reliably and economically over its full life, and to avoid limiting its warranty cover, the appropriate
inspection and service schedule must be followed. Inspection and Service intervals are determined by the number of unit operating hours and by the
age of the unit. Examples are shown in the table below. Your Dealer will prepare a schedule to suit your specific needs.
SERVICE RECORD
Each inspection and service performed should be recorded on the Service Record Sheet found at the back of this Manual
WARRANTY INSPECTION
Your Thermo King Dealer must inspect your unit, before the end of the first year of operation.This is so that your second year of warranty cover can be
activated. Your Dealer will arrange for this inspection to coincide with a scheduled inspection or service event. This is illustrated in the table above.
Operating hours per year
1000
2000
3000
Inspection
6 months/ 500 hours
Inspection
12 months/ 1000 hours
(+ warranty Inspection)
6 months/ 1000 hours
4 months/ 1000 hours
Inspection
18 months/ 1500 hours
12 months/ 2000 hours
(+ warranty Inspection)
8 months/ 2000 hours
Full Service
24 months/ 2000 hours
18 months/ 3000 hours
12 months/ 3000 hours
(+ warranty Inspection)
(continue as above)
(continue as above)
(continue as above)
Summary of Contents for SLX SPECTRUM
Page 1: ...i English 1 Fran ais 27 Italiano 57 Deutsch 85 Espa ol 115 Nederlands 145 Polski 171...
Page 2: ...ii...
Page 3: ...SLX 100 200 300 400 and SLX Spectrum w SR 2 TK 53232 2 OP Rev 4 11 08 En...
Page 29: ...SLX 100 200 300 400 et SLX Spectrum avec SR 2 TK 53232 2 OP d 4 11 08 Fr...
Page 58: ...56 D CLARATION DE CONFORMIT...
Page 59: ...SLX 100 200 300 400 e SLX Spectrum con SR 2 TK53232 2 OP Vers 4 11 08 It...
Page 87: ...SLX 100 200 300 400 und SLX Spectrum mit SR 2 TK 53232 2 OP Aufl 4 11 08 De...
Page 117: ...Unidades SLX 100 200 300 400 y SLX Spectrum con controlador SR 2 TK 53232 2 OP Vers 4 11 08 Es...
Page 146: ...144 DECLARACI N DE CONFORMIDAD...
Page 147: ...SLX 100 200 300 400 en SLX Spectrum met SR 2 TK 53232 2 OP versie 4 11 08 NL...
Page 173: ...SLX 100 200 300 400 i SLX Spectrum ze sterownikiem SR 2 TK 53232 2 OP wer 4 11 08 Pl...