15
CONTROLLER DESCRIPTION
6. Turn the unit off to stop a Pretrip Test at any
time. This will generate Alarm Code 28–
Pretrip Abort. Other alarm codes may also be
generated. This is normal when the Pretrip
test is halted before completion.
7. When all tests are complete, the results are
reported as “PASS”, “CHECK” or “FAIL”. If
the results are Check or Fail, the
accompanying alarm codes will direct the
technician to the cause of the problem.
8. When the non-running test are complete the
unit will start automatically and continue
with the Running Pretrip Test.
9. If the Pretrip Test results are Check or Fail
the problem should be diagnosed and
corrected before the unit is released for
service.
Hourmeters Menu
Hourmeters can be viewed
in the Hourmeters Menu as follows:
1. Press the MENU soft key on the Standard
Display.
2. Press the NEXT and BACK soft keys as
required to show the Hourmeters Menu.
3. Press the SELECT soft key to enter the
Hourmeters Menu.
4. Press the NEXT and BACK soft keys to
view the hourmeter displays.
Mode Menu
Operating modes between
CYCLE-SENTRY mode and Continuous Run
mode as follows:
1. Press the dedicated Cycle Sentry/Continuous
key. (See “SLX Single-temperature SR-2
Controller Display” on page 9.)
2. Press the NEXT and BACK soft keys as
required to show the Mode Menu.
3. Press SELECT soft key to enter the Mode
Menu.
4. Press the SELECT soft key, to switch
between modes.
5. The new mode is then confirmed for 10
seconds. The display then returns to the
Mode Menu. Press the SELECT soft key
again to change the mode again.
Electric Standby/Diesel Mode
Select Electric
Standby/Diesel Mode as follows:
1. Press the MENU soft key on the Standard
Display.
2. Press the NEXT soft key as required to
display the Electric Standby/Diesel Mode
Screen.
3. Press the SELECT soft key to select the
mode shown on the display.
Adjust Brightness
Allows the operator to
adjust the display intensity as follows:
1. Press the MENU soft key on the Standard
Display.
2. Press the BACK and NEXT soft keys as
required to show the Adjust Brightness
Menu.
3. Press the + or - soft keys to select the desired
brightness.
4. Press the YES soft key to enter the new
brightness level.
5. The selected level appears on the screen.
6. The Adjust Brightness Main Menu Screen
reappears and if no keys are pressed the
Standard Display appears.
Time
Allows the operator to view the Time and
Date. The Time is displayed in 24 hour military
time.
1. Press the MENU soft key on the Standard
Display.
2. Press the NEXT soft key until the Time
Display appears.
3. Press the SELECT soft key to view the time
and date.
Summary of Contents for SLX SPECTRUM
Page 1: ...i English 1 Fran ais 27 Italiano 57 Deutsch 85 Espa ol 115 Nederlands 145 Polski 171...
Page 2: ...ii...
Page 3: ...SLX 100 200 300 400 and SLX Spectrum w SR 2 TK 53232 2 OP Rev 4 11 08 En...
Page 29: ...SLX 100 200 300 400 et SLX Spectrum avec SR 2 TK 53232 2 OP d 4 11 08 Fr...
Page 58: ...56 D CLARATION DE CONFORMIT...
Page 59: ...SLX 100 200 300 400 e SLX Spectrum con SR 2 TK53232 2 OP Vers 4 11 08 It...
Page 87: ...SLX 100 200 300 400 und SLX Spectrum mit SR 2 TK 53232 2 OP Aufl 4 11 08 De...
Page 117: ...Unidades SLX 100 200 300 400 y SLX Spectrum con controlador SR 2 TK 53232 2 OP Vers 4 11 08 Es...
Page 146: ...144 DECLARACI N DE CONFORMIDAD...
Page 147: ...SLX 100 200 300 400 en SLX Spectrum met SR 2 TK 53232 2 OP versie 4 11 08 NL...
Page 173: ...SLX 100 200 300 400 i SLX Spectrum ze sterownikiem SR 2 TK 53232 2 OP wer 4 11 08 Pl...