Operating Instructions
51
Figure 33: Engine Start Screen
After the engine is started the display returns to the Standard
Display of temperature and setpoint.
Starting the Electric Motor
Units equipped with the SmartPower option only.
When standby power is connected, electric motor starting is
automatic in both Continuous Mode and Cycle Sentry Mode.
The motor will start as required when the unit is turned on. If
any keys are being pressed on the HMI control panel prior to
the motor start, the motor start will be delayed until 10 seconds
after the last key is pressed.
CAUTION: The motor may start
automatically any time the unit is turned on.
When the motor is preparing to start the HMI control panel will
display the motor start screen, as shown in Figure 34. The
preheat buzzer sounds for 20 seconds before the electric motor
starts.
Figure 34: Motor Start Screen
After the motor is started the display returns to the Standard
Display of temperature and setpoint.
Switching from Diesel to Electric
Units equipped with the SmartPower option only.
If the Electric to Diesel Autoswitch Enabled feature in
Guarded Access is set YES then the unit will automatically
switch to Electric Mode operation when standby power is
connected and available.
Summary of Contents for Precedent C-600M
Page 2: ......
Page 58: ...Operating Instructions 56 Figure 44 Initiating a Manual Defrost Cycle Defrost Key...
Page 71: ...Operating Instructions 69 Figure 61 Performing a Pretrip Test 2 From Figure 60...
Page 85: ...Operating Instructions 83 Figure 83 Displaying and Clearing Alarm Codes 1 See Figure 84...
Page 86: ...Operating Instructions 84 Figure 84 Displaying and Clearing Alarm Codes 2 From Figure 83...
Page 165: ......