Alarm Codes
128
48
Check Belts/Clutch
If unit is shutdown, repair immediately. Otherwise, report alarm at
end of day.
X
49
Check Spare Sensor 1
Report alarm at end of day.
X
50
Reset Clock
Report alarm at end of day.
X
52
Check Heat Circuit
If unit is shutdown, repair immediately. Otherwise, report alarm at
end of day.
X
54
Test Mode Timeout
Clear alarm and restart unit.
X
56
Check Host Evap Fan Low Speed
If unit is shutdown, repair immediately. Otherwise, report alarm at
end of day.
X
57
Check Host Evap Fan High Speed
If unit is shutdown, repair immediately. Otherwise, report alarm at
end of day.
X
61
Low Battery Voltage
If unit is shutdown, repair immediately. Otherwise, report alarm at
end of day.
X
62
Ammeter Out of Calibration
If unit is shutdown, repair immediately. Otherwise, report alarm at
end of day.
X
Table of Alarm Codes (Continued)
Code Description
Operator Action
Level Of
Action
Ok
T
o
Run
Check
Sh
ut
Dow
n