![background image](http://html1.mh-extra.com/html/thermo-king/precedent-c-600m/precedent-c-600m_operators-manual_1104347109.webp)
Operating Instructions
107
Figure 115: Prompt For Switch to Diesel Mode
•
Pressing the YES Soft Key will switch unit operation back
to Diesel Mode.
•
Pressing the NO Soft Key will allow the unit to remain in
Electric Mode even though standby power is not available.
The unit will not run and Alarm Code 91 Check Electric Ready
Input will be set as a prevent alarm.
Switching from Electric to Diesel
If the unit is running in Electric Mode and the Guarded Access
> Electric to Diesel Autoswitch Enabled feature is set YES
then the unit will automatically switch to Diesel Mode
operation when standby power is no longer available. The
screens shown below will not appear.
If the Diesel to Guarded Access > Electric Autoswitch Enabled
feature is set NO and standby power is disconnected or fails,
the unit will not automatically switch to Diesel mode. This is
primarily designed to prevent unauthorized diesel engine starts
when the truck is indoors or on a ferry where engine operation
is strictly prohibited.
From the Standard Display, press the MENU Key (Figure 116).