Operating Instructions
42
The display briefly shows OFF (Figure 16) and then goes
blank. To start the unit again, press the ON hard key.
Figure 16: OFF Displayed
Two Zone Standard Display
Figure 17: Two Zone Standard Display
The Standard Display is the default display that appears if no
other display function is selected. A 2 Zone Standard display is
shown here. The 2 Zone Standard Display in Figure 17 shows
the return air temperature and setpoint for two zones. The
absence of the Cycle Sentry Icon at the top of the display
shows that the unit is operating in Continuous mode. The
return air temperature for Zone 1 is -8.2°F with a -10°F
setpoint. The down-pointing arrow indicates that Zone 1 is
cooling. The return air temperature for Zone 2 is 35.8°F with a
35°F setpoint. The down-pointing arrow indicates that Zone 2
is also cooling. The soft key under each zone allows the
Setpoint for that zone to be changed. In addition, the soft key
under Zone 2 is used to turn that zone on and off. The soft key
labeled MENU allows the Main Menu to be selected.