Alarm Codes
125
11
Unit Controlling on Alternate Sensor
(Zone)
Manually monitor load temperature. Report alarm at end of day.
X
12
Sensor Shutdown (Zone)
The unit is no longer able to operate and has been shut down.
Repair immediately.
X
13
Sensor Calibration Check (Zone)
Manually monitor load temperature. Report alarm at end of day.
X
17
Engine Failed to Crank
If unit is shut down repair immediately. Otherwise, report alarm at
end of day.
X
18
High Engine Coolant Temperature
If unit is shutdown repair immediately. Otherwise, report alarm at
end of day.
X
19
Low Engine Oil Pressure
It unit is shutdown repair immediately. Otherwise report alarm at
end of day.
X
20
Engine Failed to Start
If unit is shutdown repair immediately. Otherwise, report alarm at
end of day.
X
21
Cooling Cycle Check (Zone)
Manually monitor load temperature. Report alarm at end of day.
X
22
Heating Cycle Check (Zone)
Manually monitor load temperature. Report alarm at end of day.
X
Table of Alarm Codes (Continued)
Code Description
Operator Action
Level Of
Action
Ok
T
o
Run
Check
Sh
ut
Dow
n
Summary of Contents for Precedent C-600M
Page 2: ......
Page 58: ...Operating Instructions 56 Figure 44 Initiating a Manual Defrost Cycle Defrost Key...
Page 71: ...Operating Instructions 69 Figure 61 Performing a Pretrip Test 2 From Figure 60...
Page 85: ...Operating Instructions 83 Figure 83 Displaying and Clearing Alarm Codes 1 See Figure 84...
Page 86: ...Operating Instructions 84 Figure 84 Displaying and Clearing Alarm Codes 2 From Figure 83...
Page 165: ......