Thermann Installer's Manual
Gas Continuous Flow Water Heaters
Plumbing Applications
Recirculation System
Cold Water Supply
Gas Supply
Aquastat(*3)
Pump Control Signal(*2) Only TH50ECR6 series
Relay for Pump
Hot Water
Optional 30-40 L
Storage Tank
(To alleviate cold water sandwich)
Globe
Valve
Pump(*1)
Expansion Tank
(Install according
to local code)
Fixtures
Hot Water Return
Notes:
1. Size the pump to provide a maximum of 7.5 L/min. through the system at 3m of head plus piping losses.
Adjust the flow using a globe valve and verify the flow rate with the maintenance monitors.
2. Pump Control Signal is the preferred method to control the recirculation pump.
A relay connection must be used. Only TH50ECR6 series.
If the Pump Control Signal is not used, an Aquastat may be used to control the pump.
3. Set the Aquastat to 5˚C below the set output temperature.
An aquastat is the minimum pump control requirement in order to maintain the full recirculation waranty.
Continuous Flow
Water Heater
26