Thermann Installer's Manual
Gas Continuous Flow Water Heaters
Quick Connect Multi System Installation
Make this distance as short
as possible.
* The hot water temperature
will become unstable as the
pipe length increases.
Union
Quick Connect
cord
Union
Union
Hot Water
Cold Water
Size the piping to allow for the
maximum flow rates of the units.
To drain outlet
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
To drain outlet
Gas Valve
Shutoff
Valve
Shutoff Valve
Shutoff Valve
The backflow preventer is
put up before it diverges.
Distance at center:
485-950mm (TH50ECR6)
469-950mm (TH32ECR6)
355-950mm (TH28ENR6)
Distance on sides
5-470mm (TH50ECR6)
5-486mm (TH32ECR6)
5-600mm (TH28ENR6)
G
Quick Connect
Cord
Remote Controller Cord
Gas Supply Piping
Cold Water Supply
Hot Water
Remote Controller
Terminal Block
Cord
Connector
Cord
Connector
• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord.
Typical Plumbing
* When connecting two units, use only a
single remote controller.
* The remote controller terminal location
may differ depending on the unit.
Note: Connect the remote
controller to only one of
the units.
System Diagram
The Quick Connect Cord is 2m long. Install the units to ensure the cord will be able to reach between
the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach, but the water
temperature may also become unstable because of the difference in pipe length between the two units).
• Insulate the hot water piping to prevent heat loss. insulation and apply heating materials to the cold water
supply piping to prevent heat loss and freezing of pipes when exposed to excessively cold temperatures.
12
Summary of Contents for TH28ENR6L
Page 9: ...Component Details Example TH50ECR6 series model shown for illustration only Ex TH50ECR6 9 ...
Page 11: ...TH28ENR6 series model shown for illustration only Ex TH28ENR6 11 ...
Page 49: ...49 Memo ...
Page 50: ...Thermann Installer s Manual Gas Continuous Flow Water Heaters 50 Memo ...
Page 51: ...51 Memo ...
Page 52: ......