Connecting Remote Controller Cord to Unit
• Tie the excess cord outside the water heater. Do not put the extra length inside the water heater.
• The remote controller cord can be extended up to 100m.
• Be sure to hand tighten when screwing to the terminal block. Power tools may cause damage to
the terminal block.
• When changing the temperature, make sure to confirm with the customer that the temperature of
the hot water will be very high and that there is a risk of scalding.
WARNING
Remote controller cord
(TH50ECR6 series)
• Use remote controller cord for any extensions.
• Install according to the National Electrical Code and all applicable local codes.
1. Check to make sure that the remote controller cord has plenty of slack in order to reach the external
connection terminal block.
2. Disconnect electrical power to the water heater.
3. Remove the single screw securing the terminal block cover and then remove the cover.
4. Pass the remote controller cord through the wiring throughway and connect the Y terminals at the
end of the remote controller cord to the terminal block.
5. Replace the terminal block cover and install the screw previously removed in step 3.
6. Reconnect electrical power to the water heater.
External connection
terminal block
Wiring throughway
Remote controller cord
29
Summary of Contents for TH28ENR6L
Page 9: ...Component Details Example TH50ECR6 series model shown for illustration only Ex TH50ECR6 9 ...
Page 11: ...TH28ENR6 series model shown for illustration only Ex TH28ENR6 11 ...
Page 49: ...49 Memo ...
Page 50: ...Thermann Installer s Manual Gas Continuous Flow Water Heaters 50 Memo ...
Page 51: ...51 Memo ...
Page 52: ......