Connecting the pump control wire
1. Leave enough slack so that the pump control wires
will stay connected if the unit is removed from the
wall.
2. Remove the front cover of the heater (4 screws).
3. Cut off the connector at the end of the pump
control wires.
4. Wire the pump control wires through the wiring
throughway and connect them to the relay for the
pump (Do not directly connect to the pump).
The voltage from these wires as the signal to close
a normally open relay through which 100VAC will be
supplied directly from a wall circuit to the pump.
5. Replace the front cover.
Pump Wiring
(Only TH50ECR6 series)
* This feature is not available when using
the Quick Connect Multi System feature.
Relay connection with pumps
1. Locate and prepare the pump control wires as described above.
2. Choose a suitable installation location for the relay where it will be protected from moisture.
3. Connect the pump control wires from the heater to the signal input on the relay.
4. Cut one of the electrical supply leads and wire it across the open terminals of the relay.
5. Secure all connections.
Circulation Pump
230 - 240VAC
Relay
Connect to Pump Control
Wires in Unit
0
1
2
4
PUMP
Crimping Terminal
Wiring
Throughway
Supplies Power for
Relay
PUMP RELAY Tag
31
Summary of Contents for TH28ENR6L
Page 9: ...Component Details Example TH50ECR6 series model shown for illustration only Ex TH50ECR6 9 ...
Page 11: ...TH28ENR6 series model shown for illustration only Ex TH28ENR6 11 ...
Page 49: ...49 Memo ...
Page 50: ...Thermann Installer s Manual Gas Continuous Flow Water Heaters 50 Memo ...
Page 51: ...51 Memo ...
Page 52: ......