Thermann Installer's Manual
Gas Continuous Flow Water Heaters
(1) Open a hot water fixture and confirm that the Burner on lamp comes on, and that hot water is being
produced. (If necessary, repeat until the air in the gas piping is bled out).
* White smoke may be noticed from the exhaust flue during cold weather. However, this is not a
malfunction of the unit.
* If an “11” error code appears on the remote controller, turn the unit off and then back on again,
and then open a hot water fixture again.
(2) Change the temperature setting on the remote controller and check that the water temperature changes.
• If the water heater does not operate normally, refer to “Troubleshooting” in the Owner's Guide.
* After the trial operation, clean the filter in the cold water inlet.
The installer should test operate the unit, explain to the customer how to use the unit, and give the
owner this manual before leaving the installation.
• Preparation ........... (1) Open a hot water fixture to confirm that water is available, and then close the
fixture.
(2) Open the gas supply valve.
(3) Turn on the power supply. Using the remote controller, turn on the Power
ON/OFF button (the Operation lamp will turn on).
Handling after trial operation
• If the unit will not be used immediately, close off all gas and water shut off valves, drain all of the
water out of the unit and the plumbing system to prevent the unit and system from freezing, and
bleed the gas out of the gas line.
Freezing is not covered by the warranty.
CAUTION
Trial Operation
<If installed with a quick connect multi-system>
• Turn the system power ON with the remote controller.
• Slowly open a hot water fixture and check that the units ignite sequentially. Check to see that the hot
water temperature is the same as the temperature displayed on the remote controller (*1)
* If both units do not ignite, switch which unit will ignite first by pressing the Max. or Min. Mani-fold
Pressure Set Button on the circuit board. (*2)
* If an 11 or F11 error code flashes on the remote controller, hit the Power Button on the remote controller
off and on 2 -3 times.
* If (*1) and (*2) cannot be done, the Quick Connect Cord may not be properly connected.
Check that the cord is properly connected.
Unit A Ignites
Unit B Doesn't Ignite
Press Max. or Min. Burner Gas
Pressure Set Button on Unit B
Unit A Doesn't Ignite
Unit B Ignites
34
Summary of Contents for TH28ENR6L
Page 9: ...Component Details Example TH50ECR6 series model shown for illustration only Ex TH50ECR6 9 ...
Page 11: ...TH28ENR6 series model shown for illustration only Ex TH28ENR6 11 ...
Page 49: ...49 Memo ...
Page 50: ...Thermann Installer s Manual Gas Continuous Flow Water Heaters 50 Memo ...
Page 51: ...51 Memo ...
Page 52: ......