Thermann Installer's Manual
Gas Continuous Flow Water Heaters
Specifications
Model Name
TH50ECR6N
TH50ECR6L
Approval certification number
SAI-400353
Type
Installation
Outdoor, Wall Mounted
Air Supply/Exhaust
Power Flue
Operating Pressure
200 -800 kPa
Minimum Flow Rate
2.0 L/min.
Dimensions
830mm (Height) x 480mm (Width) x 360mm (Depth)
Weight
50 kg
Water Holding Capacity
3.5 L
Connection Sizes
Water Inlet
R 1 (25mm)
Hot Water Outlet
R 1 (25mm)
Gas Inlet
R3/4 (20mm)
Power Supply
Supply
230 - 240 VAC (50Hz)
Consumption
NG/ULPG: 83 W/77 W Freeze Prevention 288W
Burner Injector Size
NG/ULPG : 1.6mm / 2.6mm
NG/ULPG : 0.9mm / 1.4mm
Accessories
Remote Controller, Remote Controller Cord, Anchoring Screws
Gas
Consumption
NG
328 MJ/hr
ULPG
328 MJ/hr
Maximum Hot Water
25°C Rise
50 L/min
Model Name
TH32ECR6N
TH32ECR6L
Approval certification number
SAI-400264
Type
Installation
Outdoor, Wall Mounted
Air Supply/Exhaust
Power Flue
Operating Pressure
200 -1,000 kPa
Minimum Flow Rate
2.5 L/min.
Dimensions
615mm (Height) x 464mm (Width) x 240mm (Depth)
Weight
32 kg
Water Holding Capacity
2.0 L
Connection Sizes
Water Inlet
R 3/4 (20mm)
Hot Water Outlet
R 3/4 (20mm)
Gas Inlet
R 3/4 (20mm)
Power Supply
Supply
230 - 240 VAC (50Hz)
Consumption
NG/ULPG: 75.9 W/75.9 W Freeze Prevention 223W
Burner Injector Size
NG/ULPG : 2.4mm / 1.7mm
Accessories
Anchoring Screws
Gas
Consumption
NG
217 MJ/hr
ULPG
217 MJ/hr
Maximum Hot Water
25°C Rise
32 L/min
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water pressure, water supply, piping conditions, and
water temperature.
14
Summary of Contents for TH28ENR6L
Page 9: ...Component Details Example TH50ECR6 series model shown for illustration only Ex TH50ECR6 9 ...
Page 11: ...TH28ENR6 series model shown for illustration only Ex TH28ENR6 11 ...
Page 49: ...49 Memo ...
Page 50: ...Thermann Installer s Manual Gas Continuous Flow Water Heaters 50 Memo ...
Page 51: ...51 Memo ...
Page 52: ......