116
4-8-6. Demo Outputs
Background
The Demo outputs on
the front panel are multi-
function outputs that can
be configured as a probe
compensation output, a
trigger output signal or to
output a number of
waveforms for
demonstration purposes.
Demo
Waveforms
Outputs
Mode
Demo Outputs
Analog
Demo 1
Trigger Output
OR
Pulse Signal:
Burst frequency: 100kHz,
Burst duration: 500uS (50 pulses)
Burst Period: 1mS
Demo 2
FM: 100kHz~1MHz
Demo 3
Probe Compensation output,
1kHz~200kHz, Duty Cycle
5%~95%
UART
Demo 1
Tx: 115200 baud, 8 data bits, no
stop bit
Demo 2
Rx, 115200 baud, 8 data bits, no
stop bit
Demo 3
Probe Compensation output,
1kHz~200kHz, Duty Cycle
5%~95%
I2
C
Demo 1
SCLK, 20kHz
Demo 2
SDA, ID=0x52
Demo 3
Probe Compensation output,
1kHz~200kHz, Duty Cycle
5%~95%
SPI
Demo 1
SCLK, 50kHz
Demo 2
SS
Demo 3
MOSI
Panel Operation/
Parameter
1. Press the
Utility
key.
Utility
2. Press
Demo Output
on the lower
menu.