12.7. Appendix 7: AA-697/P16 16 button interface board
AA-697/P16
Interface card to the AA-600 module for the management
of 16 buttons or external contacts free of voltage.
The card has removable terminals to which the external button cables are
connected. Please note that there are no common points, each button must
be connected with 2 wires to the 2 points of the specific terminal. The mini
10-way connector, which can be connected both above and below (parallel
JV1 or JV2) will be inserted in the AD600 receptacle as an alternative to the
optional keyboard. After connecting the 10-way connector on the AA-600
module, the printed circuit LED D1 will light up. On terminals JA1 and JA2
(Duplicates, parallel) it is possible to take a voltage of 12Vdc or 24Vdc
generated by the AA-600 module for external uses provided that the
maximum absorption of 200mA is not exceeded.
Detail of the connection of the wires between the connector
and the components (standard cable length = 250mm)
1
2
..
..
..
9
10
10 9 8 7 6 5 4 3 2 1
PIN 1 +VRADK
PIN 2 GND
PIN 3 COL1
PIN 4 COL2
PIN 5 COL3
PIN 6 COL4
PIN 7 ROW1
PIN 8 ROW2
PIN 9 ROW3
PIN 10 ROW4
1 2 3 4 5 6 7 8
9
C A - +
P1 + Mic
ETH
LAN
Keub/Rs485/Spk.
+Led
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
P13
P14
P15
P16
LED
Cable with 10-way connectors
10-way
connector
+ 12-24Vdc
GND
AA-600/SM5x
CAUTION: the cables connected
to the terminals must be free of
electrical voltages (only “clean”
contacts), otherwise the AA-600
device will be permanently
damaged!
Any current drawn for external
use from terminals JA1 and JA2
cannot exceed a maximum
absorption of 200mA.