TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN
Page 14 of 56
Removable 9-pole terminal block (screw connector connected to the electronic module)
1 IN1
Terminal block for the detection of the alarm contact
2 GND
Terminal block referred to the negative of the system power supply, for the alarm contact
3 K2.NA
Terminal block of the K2 relay - NO contact, normally open
4 K2.CC
Terminal block of the K2 relay - CC contact, central contact (contact load max 30V 1.5A)
5 K1.NA
Terminal block of the K1 relay - NO contact, normally open
6 K1.CC
Terminal block of the K1 relay - CC contact, central contact (contact load max 30V 1.5A)
7 K1.NC
Terminal block of the K1 relay - NC contact, normally closed
8 SP1-
Class-D amplifier 1st output terminal block for connection of a speaker, negative pole
9 SP1+
Class-D amplifier 1st output terminal block for connection of a speaker, positive pole
LAN RJ45 port (present on the electronic module)
The module needs a cable to connect to the LAN network. If the cable also carries the PoE power supply, it will not
be necessary to power the module with other power sources (for a maximum power of 10W of any added internal
audio amplifier). For higher powers an external 24Vdc 2A or max 18Vac 2.5A power supply will be required. See
also appendix 2 for LAN cable wiring at the end of the manual.
Removable 4-pole terminal block (screw connector connected to the electronic module)
C
Terminal block to power the system, irrelevant polarity
A
Terminal block to power the system, irrelevant polarity
+Vout
Terminal block from which it is possible to withdraw power supply, POSITIVE
GND
Terminal block from which it is possible to withdraw power supply, NEGATIVE
NOTE:
All the other connectors that may be present on the module sides can change function according to the models and
are linked to the specific model of installation of the purchased AD-600 module (see commercial documentation for
the models available).
Devices powered via PoE (Power over Ethernet) must only be connected with cables coming from
inside the building, LAN cable connections coming from outside the building are not allowed.
At the "+ Vout" output there is a + 12Vdc voltage if the device is powered via PoE, otherwise, on this
output the same voltage will be present on the A-C terminals. The use of "+ Vout" is permitted
provided that a maximum current consumption of 200mA is not exceeded and that the user load has
the protection on the input current. Improper use of this output will permanently damage the device.
On terminals 1 (ING1) and 2 (GND) only one relay contact or a button free of any voltage must be
connected to avoid permanent damage to the device.