9.10. Relay and alarm input settings
On this page it is possible to choose the operating mode of the two internal device relays and the operating mode
for external inputs:
•
Mode
: sets the function to be associated to the relay. It is possible to choose between:
1 Electric lock: is activated only upon receiving the activation code.
2 In call: is activated when a call is in progress and until the door phone does not come back to idle
3 In call + timer: it activated when a call is in progress and for the activation time
4 Pressure button: you press any key relay is activated for the time set
5 Whole cycle: the relay 1 remain activated for all the duration of the communication
Only for the relay 2
5 After relay 1: When you operate the relay 1, relay 2 is activated also for the time set
6 Twilight: In this mode the relay is activated 30 minutes before sunset and 30 minutes after sunrise.
The calculation of sunrise and sunset is done automatically by the system based on the current
time and location of the installation (the exact time should be obtained from the internet).
•
Activation D - N - I
: enter here any sequence to dial, from the outside, to activate the corresponding relay
•
PHONE activation
: relay activation code to dial from the extension of the PBX (2 characters required)
•
Activation time
: activation time of the relay
•
Activation delay
: for relay 2, after how many seconds you have to turn with respect to the activation of relay
1 (if set in "after Relay 1")
•
Close call
: by setting this option, your call is immediately hang up when the relay is activated