TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN
Page 22 of 56
9.6. Set of the operating mode Day/Night/Interval, Keyboard
In the operating mode, it is possible to set the mode to DAY / NIGHT / INTERVAL, either manually or automatically
(following time slots per week). This page is also configured to change the codes to the remote phone and
coordinates the installation (used to relay Twilight mode 2, see par.9.10):
•
Current mode
: allows you to set the current mode of operation.
•
Chenge mode codes
: enter the codes to change it remotely (from any internal phone, call the door phone
and, at the answer, via DTMF type the code corresponding to the selected mode). The codes must consist
of 2 characters.
•
Time bands
: in the case of automatic operation, it is possible to enter up to 5 bands per day. If a field is left
blank, it is unused so the band corresponding to the previous
•
Time zone
: time zone of the location where the installation is made (+1 for Italy)
•
Latitude/Longitude
: Geographical decimal coordinates relative to the installation site. Can be retrieved
easily from the internet (eg www.mapcoordinates.net/en)
The time zone and the geographical coordinates are needed in the case of activation of relay 2 in "Twilight" mode
(see par 9.10) to signal an external lighting system to activate at nightfall and deactivate in the morning according
to pre-established times and depending on the geographical position.