TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN
Page 19 of 56
9.4. SIP parameters
Once the network parameters have been set correctly, you must configure the connection with the SIP-VoIP PBX:
•
SIP server address
: specify the IP address of the SIP PBX to which AA-600 should connect.
•
Port
: is the port number of the SIP PBX AA-600 which has to forward incoming calls. Generally it is the
5060, but some stations use a different port.
•
Domain
: domain where register the client
•
Outbound proxy
: some PBXs require that the extension number to call is followed by the proxy address. In
most cases this field can be left empty.
•
Local SIP port
: generally the 5060 port is used, but it is possible to specify a different number (i.e. for
particular routing tables)
•
User/password
: credentials for the registration of the extension (which obviously must have been already
created on the PBX)
•
Expiration
: indicates how many seconds the device should check the correct registration of the client
•
2
ND
SIP account
: this account is used for “Night ringer”. It is possible to configure, in the PBX, a ringer
group used in night mode, so if the doorphone is put in the same group, it will play the ringer message
(see par. 9.14) when receiving an incoming call, without answering.
•
Password
: the second account password.
•
Volume
: volume of the ringer. It is also the volume used to reproduce the prerecorded announcements.
•
Ampli on
: no function in this model
•
Relay 2
: when the call is going on, it’s possible to activate the relay 2. It could be useful for example to
connect a light, a flash, etc.