![Telit Wireless Solutions WE866E4-P At Commands Reference Manual Download Page 113](http://html1.mh-extra.com/html/telit-wireless-solutions/we866e4-p/we866e4-p_at-commands-reference-manual_1083755113.webp)
WE866E4-P AT Commands Reference Guide
80572ST10887A Rev. 0.0
113
2018-02-16
PRELIMINAR
Y
, describes the responses and remarks for MQTT Subscribe command.
Synchronous Response
, describes the synchronous responses and remarks for MQTT
Subscribe command.
9.4.5 MQTT Disconnect
This command is used to disconnect MQTT connection. Prior to issuing this command,
user is required to establish MQTT connection.
Command Syntax
AT+NMQTTDISCONNECT=<CID>
Parameter Description
, describes the MQTT Disconnect parameters.
Response
, describes the responses and remarks for MQTT Disconnect
command.
Table 237 MQTT Subscribe Response
Responses
Remarks
OK
Success.
ERROR
If parameter is not valid.
Table 238 MQTT Subscribe Synchronous Response
Responses
Remarks
OK
Success.
ERROR
If parameter is not valid.
Table 239 MQTT Disconnect Parameters
Parameters Mandatory/Optional
Value
Description
CID
Mandatory
Value range:
0-15
Format:
Integer
Default value:
N/A
It specifies the connection ID returned
during the MQTT connect command.