9.2.6 Socket Information
This command is used to get the information of the socket. Prior to issuing this command,
user is required to establish L2 and L3 connection.
Command Syntax
AT+SI=<CID>
Table 165 Socket Create Parameters
Parameters Mandatory/Optional
Value
Description
Family
Mandatory
Value range:
2-5
Format:
Integer
Default value:
0
It specifies the communication domain in
which a socket is required to be created.
Type
Mandatory
Value range:
1-3
Format:
Integer
Default value:
0
It specifies the type of socket to be created.
Protocol
Optional
Value range:
0-255,
1536-2147483647
Format:
Integer
Default value:
0
It specifies the particular protocol to be
used along with the socket.
Table 166 Socket Create Response
Responses
Remarks
OK
Success.
ERROR
If parameter is not valid.
Table 167 Socket Create Synchronous Response
Responses
Remarks
OK
Success.
ERROR