Getting Started Guide
LM10Zi-GSM-E Rev A
99
MultiStage Triggers
- varied forms of triggers including
Cascaded
,
QualFirst
, and
Qualified
allowing varied combinations of triggers
and trigger stages.
Serial Triggers
- provide serial data protocol specific triggering for
a wide variety of standards.
Trigger Types
A set of standard trigger types is available for selection. These triggers
are basic waveform features or conditions such as a positive or negative
slope and are available on all oscilloscopes, along with tools like
Software Assisted Trigger
and
Trigger Scan
.
There are more sophisticated triggers for setting complex conditions.
These include
Smart Triggers
,
Serial Trigger
,
Measurement Triggers
,
and
MultiStage Triggers
.
Edge
A simple trigger, Edge trigger is activated by basic waveform
features or conditions such as positive or negative slope, and
holdoff.
NOTE
: Up to 15 GHz bandwidth is available while Edge Triggering
(provided no holdoff is selected).
Width
Width
trigger allows you to define a positive- or negative-
going pulse width bounded by a voltage level, above or below
an occurring trigger. Or you can specify a pulse width and voltage range,
within or outside an occurring trigger.
Pattern (Logic)
Logic
trigger enables triggering on a logical combination
(pattern) of five inputs: CH1, CH2, CH3, CH4, and AUX
(sometimes referred to as EXT on legacy oscilloscope
models). You have a choice of four Boolean operators (AND, NAND, OR,