Checks and Adjustments
5- 14
1705A Spectrum Monitor
h.
Change the leveled sine wave generator Frequency to 5 MHz, Amplitude
Multiplier to X1, and the Amplitude to 3.0 (14 dBm).
i.
CHECK
-- for 1 marker every 5 Divisions,
±
1 Division (adjust
CENTER FREQUENCY, if necessary).
j.
Repeat parts f. through i. with CENTER FREQUENCY at 950 MHz and
1700 MHz.
k.
Remove the leveled sine wave generator and comb generator from the
1705A L--BAND INPUT.
l.
Connect the UHF signal generator output to the 1705A L--BAND
INPUT. See Figure 5--6.
VARIABLE
AUTOTRANSFORMER
L--BAND
INPUT
UHF SINE
WAVE
GENERATOR
1705A
Figure 5-6: Using the UHF Signal Generator to check L- Band Span/Division,
Readout, Gain, and Flatness
m.
Set the UHF signal generator Amplitude to --50 dBm and Frequency to
1000 MHz.
n.
Set the 1705A SPAN/DIV to FULL. Dial the CENTER FREQUENCY
until readout reads 1000 MHz.
o.
CHECK
-- that the marker is intensified.
p.
Set SPAN/DIV to 10 MHz.
q. CHECK
-- that the marker is on screen.
r.
Position the marker under the caret with the CENTER FREQUENCY
control.
Summary of Contents for 1705A
Page 13: ...Service Safety Summary xii 1705A Spectrum Monitor ...
Page 17: ...Preface xvi 1705A Spectrum Monitor ...
Page 18: ...Introduction ...
Page 19: ......
Page 38: ...Operating Instructions ...
Page 39: ......
Page 61: ......
Page 62: ...Installation ...
Page 63: ......
Page 72: ...Theory of Operation ...
Page 73: ......
Page 93: ...Theory of Operation 4 20 1705A Spectrum Monitor ...
Page 94: ...Checks and Adjustments ...
Page 95: ......
Page 123: ...Checks and Adjustments 5 28 1705A Spectrum Monitor ...
Page 124: ...Maintenance ...
Page 154: ...Options ...
Page 155: ......
Page 158: ...Replaceable Electrical Parts ...
Page 159: ......
Page 189: ...Replaceable Electrical Parts 8 30 1705A Spectrum Monitor ...
Page 190: ...Diagrams Circuit Board Illustrations ...
Page 191: ......
Page 193: ......
Page 213: ......
Page 214: ...Replaceable Mechanical Parts ...
Page 215: ......
Page 223: ......