Checks and Adjustments
1705A Spectrum Monitor
5- 17
Adjustment Procedure
The Adjustment Procedure covers only adjustments. Checks, other than those
that must be made to ensure a step is completed, are in the Performance Check
Procedure.
There are actually two Adjustment Procedures, the short-form version is
provided for those familiar with the adjustments, while the longer (more
detailed) procedure is provided for those who need it.
Allow 20 minutes of warm-up time, at normal room temperature (approximately
25
°
C) before making any adjustments to the instrument.
The Short-Form Adjustment Procedure has the adjustment steps in the same
order as the longer form of the procedure, so the Short-Form Procedure can be
used as an index for the Long Form. Circuit numbers for parts adjusted in the
step are also included with the step title.
A1 POWER SUPPLY BOARD
1.
5 V (R99)
2.
Adjust CRT Bias (R58)
3.
Adjust Geometry (R45), Center Focus (R11) and Astigmatism (R49)
4.
Adjust Trace Rotation
A3 MAIN BOARD
5.
Adjust On-Board Regulated Power Supplies (R99, --11.8V; R111, +11.8V)
6.
Adjust Horizontal Gain (R168)
7.
Adjust Readout Position (R27, Horizontal; R29, Vertical)
8.
Adjust 360/119.8 MHz L.O. (C55, C69, L4, FL1, and FL2)
9.
Adjust Ramp Size (R113)
10.
Adjust 70 MHz Band Linearity (R55, R49, R56, R48, and R57)
11.
Adjust 10 kHz Filter (C52, C62, C64, and R175)
12.
Adjust L-Band Linearity (R35, R51, R58, R75, R81, and R82)
13.
Adjust Readout Range (R4)
14.
Adjust Span/Div Magnification Registration (R27)
Short- Form Procedure
Summary of Contents for 1705A
Page 13: ...Service Safety Summary xii 1705A Spectrum Monitor ...
Page 17: ...Preface xvi 1705A Spectrum Monitor ...
Page 18: ...Introduction ...
Page 19: ......
Page 38: ...Operating Instructions ...
Page 39: ......
Page 61: ......
Page 62: ...Installation ...
Page 63: ......
Page 72: ...Theory of Operation ...
Page 73: ......
Page 93: ...Theory of Operation 4 20 1705A Spectrum Monitor ...
Page 94: ...Checks and Adjustments ...
Page 95: ......
Page 123: ...Checks and Adjustments 5 28 1705A Spectrum Monitor ...
Page 124: ...Maintenance ...
Page 154: ...Options ...
Page 155: ......
Page 158: ...Replaceable Electrical Parts ...
Page 159: ......
Page 189: ...Replaceable Electrical Parts 8 30 1705A Spectrum Monitor ...
Page 190: ...Diagrams Circuit Board Illustrations ...
Page 191: ......
Page 193: ......
Page 213: ......
Page 214: ...Replaceable Mechanical Parts ...
Page 215: ......
Page 223: ......