31
7.3. SYSTEM USERS AND THEIR PERMISSIONS
System supports
4
types of users with different authority levels:
The Engineer
can login the system from any PC of the network, on which MSS
modules are installed, as well as from hardwired/wireless keypads. System stops
functioning while the Engineer is being logged in
the system. Default Engineer’s PIN is
«
1 2 3 4 5 6
» and it has the highest priority. The Engineer cannot control the system
(arming/disarming). The Engineer
’s account cannot be deleted from the system. The
Engineer can freely change system settings.
The Technician
can read out some settings of the system from system database in
order to carry out equipment maintenance. The Technician can arm/disarm the system
with its PIN. Technician can login the system from any PC of the network, on which
MSS modules are installed, as well as from hardwired/wireless keypads. The
Technician
doesn’t stop work of the
Operators
(see below). The Technician cannot
change system settings.
The Operator
performs system monitoring. The Operator can arm/disarm the system
with its PIN
.
The Operator cannot change system settings.
The User
can arm/disarm alarm system with its PINs
, ТМ keys, Wiagand cards,
Remote Control keyfobs in concordance with specified permissions.
Attention!
Loss of the Engineer’s PIN leads to complete reset of the Control Panel to de-
fault settings and initialization of a new system database.
Attention!
The pre-set
«Engineer» PIN code must be necessarily changed.
Summary of Contents for ASTRA ZITADEL
Page 3: ...3 15 EVENT LOG 72 16 SYSTEM USERS 75 17 LED INDICATION 85...
Page 21: ...21 6 2 ASTRA 8945 PRO COMMON WIRING DIAGRAM...
Page 22: ...22 6 3 WIRING DIAGRAM FOR SYSTEM COMPONENTS...
Page 23: ...23...
Page 24: ...24...
Page 25: ...25...
Page 26: ...26...
Page 27: ...27...
Page 28: ...28...
Page 73: ...73 3 Click Apply 4 Click Report icon to create a report...
Page 74: ...74 5 Click icon to create a list of events per shift...