13
Astra-RM
module (provides 2 additional system relay outputs).
4.2.6.
System monitoring is provided by indication panels Astra-863, wireless keypads
Astra-Z-8145 Pro, hard-wired keypads Astra-814 Pro and the Monitoring Software Suite
MSS Astra Pro.
4.2.7.
Wireless light and sound alerting is provided by means of Astra-Z-2345, wireless
evacuation signs - by means of Astra-Z-2745 (Exit sign), and wireless voice alerting - by
means of Astra-Z-2945.
4.3. PROCESSING INFORMATION
4.3.1. The Control Panel Astra-8945 Pro processes information
coming from event
sources (ES) in logical partitions assigned to them. Each system component (wired or
wireless) may have several event sources:
The body of any device which reflects its operability status.
Its address is indicated
in the MSS interface after
«#».
For example:
MC#1; RTR#2
Detection channels:
channel 1
- this is the main detection channel for wireless IR, AC, MC, etc.
detectors;
channel 2 -
this is an auxiliary detection channel implemented by ZONE
terminals on a wireless device PCB, or opening circuit of the magnets fixed to
the metal surface at detachment of vibration detector;
activated
zones
of Astra-713 hardwired zones extenders or other devices.
Detection channel is indicated in the MSS interface by the number after the
component address number and
«/».
For example:
MC#1/1; RTR#2/1
Each event source is assigned to appropriate partition with pre-set properties.
4.3.2.
An information about any violation in a logical partition is processed only in case
Summary of Contents for ASTRA ZITADEL
Page 3: ...3 15 EVENT LOG 72 16 SYSTEM USERS 75 17 LED INDICATION 85...
Page 21: ...21 6 2 ASTRA 8945 PRO COMMON WIRING DIAGRAM...
Page 22: ...22 6 3 WIRING DIAGRAM FOR SYSTEM COMPONENTS...
Page 23: ...23...
Page 24: ...24...
Page 25: ...25...
Page 26: ...26...
Page 27: ...27...
Page 28: ...28...
Page 73: ...73 3 Click Apply 4 Click Report icon to create a report...
Page 74: ...74 5 Click icon to create a list of events per shift...