INSTALLATION AND OPERATION

Smoke detector GS-503 should be installed in places where there exists possibility of 

potential fire threat. While choosing the place of installation the user should make sure 

that  the  alarm  sound  will  be  heard  from  the  whole  building.  The  device  should  be 

installed on ceiling. 

To install the device the user should:

1) Separate mounting frame (fig. 1 pos. 1) from the device body (fig. 1 pos. 2), rotating it 

counter-clockwise. 

2) Put the 9V battery, 6LR61 type (fig. 2 pos. 1).

3) Test the device by pressing the button at the front (fig. 3 pos. 1) for few seconds. After 

few sounds the button can be released. These sounds confirm that the device works 

properly.

4) Install the device on the ceiling. At first the mounting frame should be fixed to the wall 

with a use of screws and screw anchors (included in the set). Two holes on the frame 

should be used for proper wall holes placement. Next step is attaching the device 

body to the frame by inserting two characteristic hooks of the frame (fig. 4 pos. 1) into 

two channels on the device body (fig. 4 pos.2). Finally the body should be rotated 

clockwise to be fixed. 

NOTES

- You must not replace any component of the device except batteries. In case of any 

problems you should contact the service.

- The device must not be installed in places with high humidity level or in dusty space.

- The device should be installed in places that are already painted.

- The device should be installed at least 1,5m from the air conditioning. 

- The device should be tested at least once a month.

- Single repeating sounds appearing during standby mode are a low battery symptom – 

the batteries should be replaced.

The device is equipped with relay output (max. 1A) that enables to connect the device 

with an alarm system. To connect it properly one must carefully read the alarm system 

manual. Depending on the alarm control panel specification either NC (normally closed) 

or NO (normally open) joints can be used – please refer to the fig. 5-6.

GS-503

ALARM

CONTROL PANEL

LINE 1 LINE 2

LINE N

 NO

 Com

 NO

 Com

 NO

 Com

NO Com NC

GS-503

ALARM

CONTROL PANEL

LINE 1 LINE 2

LINE N

 NC

 Com

 NC

 Com

 NC

 Com

NO Com NC

Fig. 5

Fig. 6

To get some information about warranty please refer to your sales assistant. 

ALWAYS 

SAFER

SMOKE DETECTOR

GS-503

Battery 

powered

Detection

smoke

Optic alarm

Sound alarm

Test button

Relay output

RELAY OUTPUT 

TO CONNECT 

TO ALARM 

SYSTEM

BATTERY POWERED