Operation & Testing
Routine Testing of smoke detectors should be done once a month.
To test the AJ-765 smoke detectors press the test button for less than 1
second. The sounder should activate.
Any other linked detectors should also activate within 20 seconds.
The smoke detectors sounder will automatically reset, when all the smoke
has cleared.
Hush feature. When the smoke detector has been activated, pressing the
test button for less than 1 second will silence that smoke detectors sounder.
Indication:
Green Flash every 60 seconds, Detector is performing correctly
Red Flash every 8 seconds plus beep, Faulty, Clean/Replacement required
Red Flash every 50 seconds plus beep, Battery Low, Replacement required
Red Flashing with No beeping, in Hush mode for 9 minutes
*When using any aerosol smoke detector tester, please follow all instructions pro-
vided on the can. Improper use may result in degraded detector performance.
**Routine cleaning is required to ensure no false triggers.
AJ-765
Auto Resetting Smoke Detector
with Wireless Interconnect
Specifications
Detection Type:
Photoelectric Chamber
Power Source:
Battery up to 10 year life
Buzzer Output:
85db @ 3 meters
Wireless Frequency:
433MHz
Interconnect Range:
up to 50 meters apart
Dimensions:
40mm x
Ø
110mm
Operating Temp. Range: 0
˚
C to 40
˚
C
Compatible with:
AJ-718 Heat Detector
AJ-R106 Remote Test & Hush Controller
Standards:
EN14604:2005/AC:2008
& AS3786:2014
Kitchen
Dining
Room
Living
Room
Bathroom
Bedroom
Bedroom
Bedroom
Bedroom
= Must have Location (within 3 meters of every bedroom door)
= Recommended Locations
= Optional Heat Detector (AJ-718)
500mm min.
1500mm max.
300mm min.
300mm min.
500mm max.
Exposed
Beams
=Dead Air Space
(don’t fit here)
Mounting Clearances
*Always refer to latest standards/building code for mounting locations
V1.01OP