51
13)
In case there are 433 MHz wireless devices with signal level lower than 5 relative units
and they are registered in WE 433 directly, delete them from WE memory, register
additional WE in repeater mode and then register wireless devices in repeater
memory.
14)
Test system workability by irradiating each device with laser beam from Astra-942 la-
ser tester using red button. Make sure the Test message is displayed in the Monitor
window for each device. Test is available for all 2.4 GHz devices (except Astra-Z-
3245) and for two 433 MHz devices Astra-4511 RF2 and Astra-421 RF2.
If Astra-GSM module is used, Test signals can b
e delivered to user’s mobile phone.
For detailed information on test procedure, please, refer to
p.10.2
of this Guide.
15)
Carry out complex workability test of the system during at least one week, ana-
lyze system event log.
16)
Change system settings in necessary. Repeat complex workability test.