64
13.2.5. HE Astra-713
1)
Switch off the power of the
HE
, disconnect RS-485 interface
2)
Install jumper on F7 plug (on two right-hand pins)
3)
Connect Astra-984 adapter to the device. Switch device power on.
4)
Connect Astra-984 adapter to PC via USB
5)
Further procedure is the same as for Astra-8945 Pro
Note.
Serial firmware version of the hardwired extender Astra-
713 doesn’t support operat-
ing with Pro-series Control Panels. Therefore, the device firmware must be neces-
sarily updated.
13.2.6. Astra-PSTN Module, Astra-RM Module.
Firmware update is not applied.
13.2.7. Astra-GSM Module, Astra-LAN Module
1)
Both
Astra-GSM
and
Astra-LAN
modules must be registered in the system before
starting the update procedure.
2)
Connect Control Panel to PC via USB
3)
Run
FW Update Module,
wait for the Control Panel and all registered embedded
devices descriptors to be read out.
4)
Select necessary module on the
Device
tab