TE700 Instruction
Manual
IRMS 020.26kA
It indicates the value of the current with which the last weld was carried out. In WELD mode
the value may range from 000.00 kA to 200.00 kA. In NO WELD mode the value is 000.00 kA.
It represents the average of the RMS
values measured for each weld time millisecond. The
displayed value always refers to the main adjustment that is to say to that of the WELD
parameter. In the case of pulse welds, the displayed current value is the average of the RMS
values of the current supplied during the single pulses.
E 00100J
It indicates the value of the energy supplied during the welding operation. The displayed value
always refers to the energy supplied inside the weld's main block. In the case of the pulse
adjustment, the displayed value always refers to the last run pulse. The value is updated if the
control unit is in WELD mode, if the control unit is in NO WELD mode, 00000J is displayed.
The display of -----J indicates that the configuration of the set machine does not permit
measuring the energy.
r 055.4%
It indicates the use percentage of the welding unit (trans inverter). The displayed
number is directly proportional to the welding unit capacity of supplying current. Approaching
100% means approaching the max current the machine can supply. This value will depend on
the type of welding unit, the geometry of the machine and the features of the material to be
welded. Approaching 100% entails a loss of the control unit's current adjustment capacities.
The value is updated in WELD mode. 000.0% is displayed in NO WELD mode.
Use keys and inside this screen to view data relevant to the previously carried out 20
weld spots. The control unit only stores data relevant to spots carried out in WELD mode. The
execution of a weld in WELD mode and in NO WELD mode leads to the display of data
relevant to the last spot carried out in WELD mode.
Other screens containing information about the weld cycle carried out can be viewed by
pressing key
in the main work screen
.
Sequence screen
The sequence screen may be accessed only in case the sequence function has been enabled
inside the control unit.
PRG 005-FE ZN 10-01
ST 001-020 NXTPR 024
WELD 2048 RMS 010.00
SPOT 02345 r 000.0
PRG 005-FE ZN 10-01
005
Indicates the program used to carry out the last weld. The number ranges from 001 to
300. It is displayed both in WELD and NO WELD mode.
FE ZN 10
is the alphanumeric identifier associated with the selected weld program. These are
8 characters that are defined at will by the operator to better identify the weld program. It is
displayed both in WELD and NO WELD mode.
01
is the identifier of the number of the transformer used to carry out the weld or the number
of the tool used. The number ranges from 1 to 4. It is displayed both in WELD and NO WELD
mode.