TECNA
S.p.A.
ITEM
TE700 Instruction
Manual
TABLE WITH SEAM WELD OPERATING MODE PARAMETERS – SECONDARY
ADJUSTMENT
PROGRAM DATA T1
>TOOLS N° 1
WORKING MODE PWK
CONTROL MODE NO
PARAMETER RANGE
VALUE
PROGRAM N.
001 – 300
WORKING MODE
PWK
CONTROL MODE *
NO
SQUEEZE 1
0.5 – 99.0 cycles
SQUEEZE
00.0 – 99.0 cycles
PRESSURE
00.5 – 10.0 bar
MOTOR DELAY
05 - 99 cycles
PRE-WELD
0000 – 1000 mS
PRE-POWER
000.20 - 600.00 KW
COLD 1
0000 – 1000 mS
SLOPE UP
0000 – 1000 mS
WELD
0001 – 2000 mS
POWER
000.20 - 600.00 KW
CURR. MAX.
001.00 – 200.00 KA
COLD 2
0000 – 1000 mS
POWER 2
000.20 - 600.00 KW
HOLD TIME
00.5 – 99.0 cycles
CONTROL MODE *
CUR
LIM I MIN
000.30 – 200.00 KA
LIM I MAX
000.30 – 200.00 KA
CONTROL MODE *
RO
LIM RO MIN
005.0 – 100.0%
LIM RO MAX
005.0 – 100.0%
CONTROL MODE *
VE
LIM V MIN
00.20 – 20.00 V
LIM V MAX
00.20 – 20.00 V
CONTROL MODE *
PW
LIM P MIN
000.20 - 600.00 KW
LIM P MAX
000.20 – 600.00 KW
95/128