Instruction Manual
ITEM TE700
TECNA
S.p.A.
90/128
The graph below shows the time and modality of the signals used for this WORKING MODE
(with reference to the values outlined in the foregoing table).
From the moment the control unit activates the DRESSING ALARM output it may be reset at
any time by activating the DRESSING RESET input as shown in the foregoing graph for
dressings 1, 3 and 4.
In the example above, the very last spot of the dressing was reached during DRESSING no. 2
without resetting the DRESSING ALARM. In this case the control unit stops and displays the
relevant warning message (ERROR 116). In this case the operator must first delete the
screen from the control unit either through the ERROR RESET input or the CLEAR key, and
then reset the DRESSING ALARM output.
The same is applicable to clear the ELECTRODES END LIFE ALARM output.
When the ELECTRODES END LIFE CLEAR input signal is activated, the control unit resets
the spots counter.