DRESSING OFFSET
Use this parameter to increase, in percentage, the starting value of the dressings welding
current after the first one.
EXAMPLE:
The parameters outlined in the table below were set (with a set work program such as, for
example, "WORKING MODE" IK) with an initial current value set to 10KA.
PARAMETER VALUE
DRESSING NUMBER
3
SPOT DRESSING
200
DRESSING STEPS
30%
DRESSING ALARM
20
ELECTRODES ALARM
20
DRESSING OFFSET
5 %
The chart below shows the pattern of how the current increased during the electrodes
dressing run mode.
You may notice that the initial current of the first dressing begins at 10KA whilst a percentage
is added to the starting current value of the next dressing (parameter DRESSING OFFSET).
89/128