TE700 Instruction
Manual
FE ZN 10
is the alphanumeric identifier associated with the selected weld program. These are
8 characters that are defined at will by the operator to better identify the weld program. It is
displayed both in WELD and NO WELD mode.
01
is the identifier of the number of the transformer used to carry out the weld or the number
of the tool used. The number ranges from 1 to 4. It is displayed both in WELD and NO WELD
mode.
POWER 000.0KW
It indicates the average value of the power supplied during the weld's main block. The value is
updated when the control unit is in WELD mode whilst 000.0KW is displayed when the unit is
in NO WELD mode. The display of ---.-KW means that the present configuration of the control
unit does not allow viewing the supplied power value. The displayed value always refers to
the energy supplied inside the weld's main block and in the case of the pulse WORKING
MODE it always refers to the last pulse.
VE 05.00V
It indicates the average value of the RMS voltage at the electrodes carried out every
millisecond. The value is updated when the control unit is in WELD mode whilst 00.00V is
displayed when the control unit is in NO WELD mode. The display of --.—V means that the
present configuration of the control unit does not allow viewing the electrodes voltage value.
The displayed value always refers to the energy supplied inside the weld's main block and in
the case of the pulse WORKING MODE it always refers to the last pulse.
Use keys and inside this screen to view data relevant to the previously carried out 20
weld spots. The control unit only stores data relevant to spots carried out in WELD mode. The
execution of a weld in WELD mode and in NO WELD mode leads to the display of data
relevant to the last spot carried out in WELD mode.
Weld analysis screen – 2
This screen may be accessed when the programming of at least one of the following
parameters has been activated inside the control unit: pre-weld, weld 2 or post weld.
PRG 005-FE ZN 10-01
PRE 0000mS 000.00KA
POST 0000mS 000.00KA
W2 0000mS 000.00KA
PRG 005-FE ZN 10-01
005
Indicates the program used to carry out the last weld. The number ranges from 001 to
300. It is displayed both in WELD and NO WELD mode.
FE ZN 10
is the alphanumeric identifier associated with the selected weld program. These are
8 characters that are defined at will by the operator to better identify the weld program. It is
displayed both in WELD and NO WELD mode.
01
is the identifier of the number of the transformer used to carry out the weld or the number
of the tool used. The number ranges from 1 to 4. It is displayed both in WELD and NO WELD
mode.
PRE 0000mS 000.00KA
It indicates the duration in mS and the RMS welding current average during the pre-weld
block.
13/128