13.3
– WORK ERRORS
MESSAGE
N°
CAUSE
REMEDY
NO EMERGENCY
RELAY ERROR RESTART
101
The emergency signal required to run
the control unit was omitted or a relay
error occurred when the restart relay
was activated.
Carefully check the
electrical connections of the
emergency signal.
THERMOSTAT
OR FLOW METER ERROR
102
Either the protective thermostat or the
flow meter inside the welder tripped.
Check that enough water
circulates inside the welder
and/or check the working
efficiency of the thermostat.
WELD CURRENT
LIMIT LOW
201
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.
WELD CURRENT
LIMIT HIGH
202
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.
RO
LIMIT LOW
203
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.
RO
LIMIT HIGH
204
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.
SECONDARY VE
LIMIT LOW
205
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.
SECONDARY VE
LIMIT HIGH
206
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.
POWER
LIMIT LOW
207
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.
POWER
LIMIT HIGH
208
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.
ENERGY
LIMIT LOW
209
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.
ENERGY
LIMIT HIGH
210
The control unit counts some faulty
spots, the last of which has been
carried out with a current value lower
than the min. set limit.
Reset the error as
specified.