Instruction Manual
ITEM TE700
TECNA
S.p.A.
58/128
STEPPER MENU PARAMETERS TABLE
PARAMETER
PARAMETER DESCRIPTION
RANGE VALUE
TOOLS N°
Number of the tool which the
parameterization refers to
1 – 4
STEPPER WELD
Stepper of the main adjustment
parameter
OFF – ON L1 – ON L2
STEPPER TIME
Weld time increase
OFF – ON L1 – ON L2
STEPPER THICK.
Decrease of the electrodes size
OFF – ON L1 – ON L2
N.TOTAL STEPS
Total number of steps
1 – 7
SPOTS 1
Spots step 1
0 – 10000
INCREMENT 1-L1
INCREMENT percentage law 1
0 – 50 %
INCREMENT 1-L2
INCREMENT percentage law 2
0 – 50 %
SPOTS 2
Spots step 2
0 – 5000
INCREMENT 2-L1
INCREMENT percentage law 1
0 – 50 %
INCREMENT 2-L2
INCREMENT percentage law 2
0 – 50 %
SPOTS 3
Spots step 3
0 – 5000
INCREMENT 3-L1
INCREMENT percentage law 1
0 – 50 %
INCREMENT 3-L2
INCREMENT percentage law 2
0 – 50 %
SPOTS 4
Spots step 4
0 – 5000
INCREMENT 4-L1
INCREMENT percentage law 1
0 – 50 %
INCREMENT 4-L2
INCREMENT percentage law 2
0 – 50 %
SPOTS 5
Spots step 5
0 – 5000
INCREMENT 5-L1
INCREMENT percentage law 1
0 – 50 %
INCREMENT 5-L2
INCREMENT percentage law 2
0 – 50 %
SPOTS 6
Spots step 6
0 – 5000
INCREMENT 6-L1
INCREMENT percentage law 1
0 – 50 %
INCREMENT 6-L2
INCREMENT percentage law 2
0 – 50 %
SPOTS 7
Spots step 7
0 – 5000
INCREMENT 7-L1
INCREMENT percentage law 1
0 – 50 %
INCREMENT 7-L2
INCREMENT percentage law 2
0 – 50 %
TOOLS N°
This parameter allows the operator to choose on which INCREMENT module a corresponding
INCREMENT module will be available for each tool made available in the
INVERTER
FEATURES
menu. On changing the value of the parameter, all the next parameters will be
updated with the newly selected INCREMENT module.
STEPPER WELD
This parameter allows the operator to activate or deactivate the stepper of the welding
adjustment parameter. The stepper will act on the adjustment parameter selected in the
working mode of the called weld program. For example in the case of IK, the stepper will
affect the welding current, in the case of PWK the stepper will affect the power supplied
during the welding operation. The stepper of the main adjustment parameter may be left
deactivated or arbitrarily associated with one of the two available stepper laws.
STEPPER TIME
This parameter allows the operator to activate or deactivate the stepper of the parameter time
referred to the duration of each hot phase of the welding process, pre-weld time, slope-up
time, weld time, weld. 2 time, slope-down time and post-weld time. The cold weld times and