The time value is displayed both in WELD mode and in NO WELD mode. The value of the
current is displayed only in WELD mode whilst 000.00KA is displayed in NO WELD mode.
If PRE ----mS ---.—KA is displayed, this means that the programming of the pre-weld
parameter is disabled inside the control unit.
POST 0000mS 000.00KA
It indicates the duration in mS and the RMS welding current average during the post-weld
block.
The time value is displayed both in WELD mode and in NO WELD mode. The value of the
current is displayed only in WELD mode whilst 000.00KA is displayed in NO WELD mode.
If POST ----mS ---.—KA is displayed, this means that the programming of the post-weld
parameter is disabled inside the control unit.
W2 0000mS 000.00KA
It indicates the duration in mS and the RMS welding current average during the weld 2 block.
The time value is displayed both in WELD mode and in NO WELD mode. The value of the
current is displayed only in WELD mode whilst 000.00KA is displayed in NO WELD mode.
If W2 ----mS ---.—KA is displayed, this means that the programming of the weld 2 parameter
is disabled inside the control unit.
Use keys and inside this screen to view data relevant to the previously carried out 20
weld spots. The control unit only stores data relevant to spots carried out in WELD mode. The
execution of a weld in WELD mode and in NO WELD mode leads to the display of data
relevant to the last spot carried out in WELD mode.
Stepper analysis screen
This screen may be accessed only if the stepper function is activated on the control unit.
PRG 005-FE ZN 10-01
STEP 1-7 SPOT 02400
INC1 001.0 % OF 060%
INC2 023.1 % OF 030%
PRG 005-FE ZN 10-01
005
Indicates the program used to carry out the last weld. The number ranges from 001 to
300. It is displayed both in WELD and NO WELD mode.
FE ZN 10
is the alphanumeric identifier associated with the selected weld program. These are
8 characters that are defined at will by the operator to better identify the weld program. It is
displayed both in WELD and NO WELD mode.
01
is the identifier of the number of the transformer used to carry out the weld or the number
of the tool used. The number ranges from 1 to 4. It is displayed both in WELD and NO WELD
mode.
STEP 1-7
It indicates the control unit's present STEP and the total number of STEPS activated on the
stepper’s parameterization. The datum increases only when the control unit is in WELD mode
and does not increase when the unit is in NO WELD mode.