Inverter use percentage limits
Activate this mode by setting the CONTROL MODE parameter to RO.
Two new parameters will be displayed:
LIM RO MIN lower limit of the power semiconductors conduction percentage.
LIM RO MAX upper limit of the power semiconductors conduction percentage.
that permit setting limit values on the conduction percentage of the power semiconductors.
PROGRAM DATA T1
TOOLS N° 1
WORKING MODE IK
>CONTROL MODE RO
PROGRAM DATA T1
>PAUSE 00
LIM RO MIN 006.0%
LIM RO MAX 020.0%
In conduction percentage control mode (CONTROL MODE = RO), if the value of the
conduction percentage of the last weld is higher or lower than the values set in the foregoing
parameters, one of the following messages is displayed:
STOP BAD SPOT MAX T1
RO [203]
LIMIT LOW
PUSH [///] TO RESET
STOP BAD SPOT MAX T1
RO [204]
LIMIT HIGH
PUSH [///] TO RESET
Limits on secondary voltage
Activate this mode by setting the CONTROL MODE parameter to VE.
Two new parameters will be displayed:
LIM V MIN lower limit on the secondary voltage
LIM V MAX upper limit on the secondary voltage
that permit setting limit values on the secondary voltage during the welding operation
PROGRAM DATA T1
TOOLS N° 1
WORKING MODE IK
>CONTROL MODE VE
PROGRAM DATA T1
>PAUSE 00
LIM V MIN 00.50V
LIM V MAX 01.20V
In secondary voltage control mode (CONTROL MODE = VE), if the value of the secondary
voltage is higher or lower than the values set in the foregoing parameters, one of the following
messages is displayed:
STOP BAD SPOT MAX T1
SECONDARY VE [205]
LIMIT LOW
PUSH [///] TO RESET
STOP BAD SPOT MAX T1
SECONDARY VE [206]
LIMIT HIGH
PUSH [///] TO RESET